SFS Steel Framing Systems for Data Centres
Lightweight steel framing for complex technical buildings
HD Construction installs steel framing systems for new-build, expansion and refurbishment projects within the data centre sector.
SFS provides a lightweight, strong and adaptable framing solution for internal and external applications. Its precise construction and flexible layout make it well suited to buildings containing extensive mechanical, electrical and plumbing services.
Specialist SFS installation for data centres
Steel framing systems can be used to form internal walls, external infill panels, high-level partitions and support structures for specified boards and finishes.
Data centre construction requires accurate setting out and close coordination between the structural frame, external envelope, internal partitions and building services.
HD Construction works with main contractors, designers, structural engineers, façade specialists and MEP contractors to deliver accurately installed SFS packages based on the approved system design.
Our SFS services
Our data centre SFS services can include:
- External infill wall framing
- Oversail framing systems
- Internal SFS walls
- High-bay partitions
- Independent wall frames
- Parapet framing
- Plant-room walls
- Service enclosures
- Framing around equipment areas
- Framing around doors and openings
- Structural openings for building services
- Support framing for specified finishes
- Sheathing-board installation
- Membranes and insulation where specified
- Local alterations and remedial works
All systems are installed according to the approved structural design, construction drawings, project specification and relevant manufacturer requirements.
External SFS framing
External SFS can form part of the building-envelope construction, providing a lightweight framing system between or outside the primary structural frame.
Depending on the approved design, the system may support:
- Sheathing boards
- Insulation
- Breather membranes
- Vapour-control layers
- Cavity components
- Rainscreen cladding
- Other specified external finishes
The complete wall build-up must be coordinated with the façade design, fire strategy, thermal requirements and structural movement provisions.
Internal SFS framing
Internal steel framing systems can be used where greater height, strength or flexibility is required than may be provided by standard lightweight partitions.
Applications can include:
- High-level partitions
- Plant-room enclosures
- Service risers
- Equipment-area divisions
- Independent wall constructions
- Supporting walls for specified boards
- Internal structures around large openings
- Walls requiring enhanced robustness
The selected gauge, stud size, spacing, bracing and connection details must follow the approved SFS design.
Integration with mechanical electrical and plumbing services
Data centres contain extensive electrical containment, cooling equipment, ventilation, pipework and fire-protection systems.
SFS layouts must therefore be coordinated with building services before fabrication and installation. Openings should be planned so that the framing maintains its intended structural and performance characteristics.
Our coordinated approach considers:
- Cable-containment routes
- Pipe and duct penetrations
- Ventilation openings
- Access requirements
- Equipment positions
- Door and louvre openings
- Service supports
- Fire-stopping interfaces
- Internal lining requirements
- Cladding and façade connections
Structural members should not be cut, notched or altered unless the change has been reviewed and approved by the appropriate designer.
Accurate setting out
Precise setting out is essential to ensure the framing aligns with the structural frame, floor edges, internal layouts and external finishes.
Before installation, we check:
- Gridlines and control points
- Slab and structural-edge positions
- Floor levels
- Opening dimensions
- Frame tolerances
- Connection locations
- Deflection requirements
- Adjoining wall and façade build-ups
Any discrepancy that could affect the installation is raised with the project team before work proceeds.
Openings and structural interfaces
Doors, louvres, service penetrations and other openings must be incorporated into the approved framing design.
Our installation can include:
- Framed door openings
- Window and louvre openings
- Service apertures
- Structural jambs and headers
- Reinforced framing zones
- Movement and deflection details
- Connections to the primary structure
- Interfaces with concrete and steel frames
The dimensions and reinforcement requirements for each opening must follow the approved design information.
Fire thermal and acoustic performance
SFS commonly forms part of a complete wall construction designed to meet several performance requirements.
Depending on the specified build-up, the completed system may contribute to:
- Fire resistance
- Thermal performance
- Acoustic separation
- Air tightness
- Weather resistance
- Moisture management
- Impact resistance
These requirements depend on the complete tested or assessed construction, including framing, boards, insulation, membranes, fixings and interfaces.
Substitutions or changes to individual components should be reviewed by the relevant designer before installation.
Sheathing boards membranes and insulation
Where included within our scope, HD Construction can install specified components associated with the SFS frame, including:
- External sheathing boards
- Internal lining boards
- Insulation
- Breather membranes
- Vapour-control layers
- Cavity barriers
- Fire barriers
- Tapes and sealing products
These materials are installed in the correct sequence and coordinated with cladding, roofing and other envelope packages.
Our delivery process
- Review the approved design
We review the structural calculations, framing drawings, specifications, connection details and construction programme.
- Survey and coordinate
The primary structure, slab edges, levels, openings and building-service requirements are checked before installation.
- Plan materials and access
Components, lifting requirements, work areas and installation sequencing are coordinated with the wider project programme.
- Install the framing system
Tracks, studs, bracing, connections and framed openings are installed according to the approved SFS design.
- Inspect and hand over
The completed framing is checked for alignment, fixings, connections and conformity with the approved details before it is covered by following trades.
Quality-control considerations
SFS performance depends on accurate installation of the complete framing system.
Our quality-control approach focuses on:
- Correct stud and track sizes
- Approved component gauges
- Accurate stud spacing
- Correct connection types
- Required fixing centres
- Bracing and restraint
- Deflection-head details
- Opening reinforcement
- Alignment and tolerances
- Material identification
- Inspection before boarding or cladding
- Protection of completed work
Inspection requirements and hold points should be agreed before installation begins.
Why choose HD Construction
- Experience with internal and external SFS applications
- Careful interpretation of approved framing designs
- Accurate setting out and alignment
- Coordination with structural, façade and MEP teams
- Integrated drylining and cladding capabilities
- Structured inspection and quality records
- Clear communication throughout the project
- Support from initial coordination through to handover
Discuss your SFS requirements
If you require steel framing systems for a new data centre, facility expansion or refurbishment project, speak to HD Construction.
Send us your SFS drawings, structural information, specification and programme. Our team will review the package and discuss how we can support your project.
Telephone: 020 3151 8763
Email: info@hdconstruction.co.uk